Prezentace se nahrává, počkejte prosím

Prezentace se nahrává, počkejte prosím

125MOEB 2009/20101(C) CVUT FSV KTZB KK Úvod do ESP-r.

Podobné prezentace


Prezentace na téma: "125MOEB 2009/20101(C) CVUT FSV KTZB KK Úvod do ESP-r."— Transkript prezentace:

1 125MOEB 2009/20101(C) CVUT FSV KTZB KK Úvod do ESP-r

2 125MOEB 2009/20102(C) CVUT FSV KTZB KK ESP-r historie ESP-r (Environmental Systems Performance; r for "research„) Nástroj pro dynamickou simulaci budovy metodou konečných objemů a konečných diferencí založený na metodě, heat balance method. Academic, research / non commercial Vyvíjen v ESRU, Dept.of Mech. Eng. University of Strathclyde, Glasgow, UK by prof. Joseph Clarke and his team since 1974 ESP-r je šířen jako GNU General Public License. UNIX, Cygwin, Windows http://www.esru.strath.ac.uk/

3 125MOEB 2009/20103(C) CVUT FSV KTZB KK ESP-r architecture Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Save level From -To Results file dir Monitor … Graphs Timestep rep. Enquire about Plant results IEQ Electrical CFD Sensitivity IPV

4 125MOEB 2009/20104(C) CVUT FSV KTZB KK Cvičení 3 ESP-r : Analýza potřeby energie v různých klimatických podmínkách

5 125MOEB 2009/20105(C) CVUT FSV KTZB KK Cíl příkladu Naučit se spustit ESP-r Přiřadit klimatickou databázi Prohlédnout si existující model Spustit simulaci Spustit analýzu výsledků – energie a teploty Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

6 125MOEB 2009/20106(C) CVUT FSV KTZB KK Spuštění ESP-r Click on:../OfficeCTU_test/cfg/office_test.cfg Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

7 125MOEB 2009/20107(C) CVUT FSV KTZB KK Přiřazení klimatických dat Click on: database maintenance Click on : annual climate Click on: select another file Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

8 125MOEB 2009/20108(C) CVUT FSV KTZB KK Přiřazení klimatických dat Click on: database maintenance Click on : annual climate Click on: select another file Select: CZE_Prague-IWEC_115180 Confirm, ok, exit. Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

9 125MOEB 2009/20109(C) CVUT FSV KTZB KK Prohlédnutí modelu Click on: Browse, edit, simulate Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

10 125MOEB 2009/201010(C) CVUT FSV KTZB KK Prohlédnutí modelu Click on: Browse, edit, simulate Click on: Zones - Composition, Controls – zones and browse model. !!!Neklikat na nic pod položkou „NETWORKS“ !!! Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

11 125MOEB 2009/201011(C) CVUT FSV KTZB KK Spuštění simulace Click on: Browse, edit, simulate Click on: Zones - Composition, Controls – zones and browse model. Click on: Simulation Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

12 125MOEB 2009/201012(C) CVUT FSV KTZB KK Spuštění simulace Click on: Browse, edit, simulate Click on: Zones - Composition, Controls – zones and browse model. Click on: Simulation Check: zone ts/hr=1, from-to, result save level (4),results file dir Click on: Integrated simulation Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

13 125MOEB 2009/201013(C) CVUT FSV KTZB KK Spuštění simulace Click on: Integrated simulation Select: Run interactively Confirm cfg file selection Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

14 125MOEB 2009/201014(C) CVUT FSV KTZB KK Spuštění simulace Click on: Integrated simulation Select: Run interactively Confirm cfg file selection Click on: Initiate simulation Confirm results file name Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

15 125MOEB 2009/201015(C) CVUT FSV KTZB KK Spuštění simulace Click on: Initiate simulation Confirm results file name Click on: Monitor state variable Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

16 125MOEB 2009/201016(C) CVUT FSV KTZB KK Spuštění simulace Click on: Initiate simulation Confirm results file name Click on: Monitor state variable Select: All items, exit, State variable –temperature, Min Max values 0 30 Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

17 125MOEB 2009/201017(C) CVUT FSV KTZB KK Spuštění simulace Click on: Monitor state variable Select: All items, exit, State variable –temperature, Min Max values 0 30 Click on: Invoke simulation Confirm all Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

18 125MOEB 2009/201018(C) CVUT FSV KTZB KK Spuštění simulace Click on: Invoke simulation Confirm all View monitor results - interesting, isn“t it? Exit to main menu, quit – window close Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

19 125MOEB 2009/201019(C) CVUT FSV KTZB KK Spuštění analýzy výsledků Click on: result analysis Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

20 125MOEB 2009/201020(C) CVUT FSV KTZB KK Spuštění analýzy výsledků Click on: result analysis ? Energy use? Click on: Enquire about, Energy delivered Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

21 125MOEB 2009/201021(C) CVUT FSV KTZB KK Spuštění analýzy výsledků ? Energy use? Click on: Enquire about, Energy delivered Read results in text feedback window Click on:exit Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

22 125MOEB 2009/201022(C) CVUT FSV KTZB KK Spuštění analýzy výsledků ?Energy use? Click on: Enquire about, Energy delivered Read results in text feedback window Click on: exit Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

23 125MOEB 2009/201023(C) CVUT FSV KTZB KK Spuštění analýzy výsledků ? Temperature graph? Click on: Graphs, TimeVar,Temperatures,Zone db T Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

24 125MOEB 2009/201024(C) CVUT FSV KTZB KK Spuštění analýzy výsledků ? Temperature graph? Click on: Temperatures,Zone db T Click on: Draw graph Enjoy graph feedback… Project manager Climate Material Construction Plant components Event profiles Optical properties Databases maintenace Model editor Zones Networks Plant Vent/Hydro Electrical Contaminants Controls Simulation controler Results analysis Timestep Savelevel From-To Resultsfile dir Monitor … Graphs Timesteprep. Enquireabout Plantresults IEQ Electrical CFD Sensitivity IPV

25 125MOEB 2009/201025(C) CVUT FSV KTZB KK Úloha 3: Analýza potřeby energie v různých klimatických podmínkách. Otevřete OfficeCTU_test model v ESP-r. Nechte proběhnout celoroční simulaci v podmínkách Prahy a Vámi zvoleného jiného města uvedeného v klimatické databázi. Nalezněte: max a min teplotu vzduchu v zónách room 1 room 2, roční potřebu energie pro vytápění a chlazení pro zóny room 1 a room 2. Porovnejte výsledky a udělejte krátkou vysvětlující zprávu s grafem v excellu. Zprávu převeďte do pdf formátu. Odešlete emailem na adresu vyučujícího s MOEB_3 v předmětu zprávy.


Stáhnout ppt "125MOEB 2009/20101(C) CVUT FSV KTZB KK Úvod do ESP-r."

Podobné prezentace


Reklamy Google