1 ELECTRO-MAGNETIC FLOW METERS ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic 1

2  Intended for measurement of conductive liquids, mainly for clean and waste water, using in food and chemical industry  Principal on Faraday law: u i = B x l x v [μV]  Produced types: FLONET FN20XX.1 FLONET FF10XX.1 FLONET FH10XX  They don’t have any moving parts  They have min. pressure loses 2 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

3 FLONET FN20XX.1 3 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

4 FLONET FN20XX.1  Produced sizes: DN6 to DN1200 (1/4” to 48”)  Nominal pressure: from 6 to 40 bar / 150 to 600lb  Min. conductivity of measured liquid: 20μS/cm, 5 μS/cm on special request  Max. temperature of measured liquid: up to +150°C (302°F)  Material of electrodes: ss-steel 316Ti, Hasteloy, Tantalum, Titanium, Platinum  Material of lining:Hard/Soft rubber, special rubber WAGUNIT, Teflon  Material of flanges:carbon steel, ss-steel  Type of connection:flanged or wafer (up to DN200) 4 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

5 FLONET FN20XX.1  Type of flanges:EN, ANSI, AWWA, JIS, AS, BS  Design version: compact, remote (max. 50m of length of cable)  Measurement accuracy:±0,5% in range 1:20, ±0,2% in range 1:10  Measuring range:0.1 to 10 m/s  Outputs:pulse, frequency, current 0(4) to 20mA, USB and RS485  Power supply:115/230V AC, 50/60Hz, 24V DC  Ambient temperature:-5° to +55°C (23° to 131°F)  Protection class:IP65/ IP67/IP68 5 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

6 FLONET FN20XX.1 Rated internal diameter a sensor length 6 Design versionCOMPACTREMOTE ConfigurationECONOMICCOMFORTECONOMICCOMFORT Type designationFN20X0.1FN20X4.1FN20X1.1FN20X5.1 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

7 FLONET FN20XX.1 7 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

8 FLONET FF10XX.1 8 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

9 FLONET FF10XX.1  Produced sizes: DN10 to DN100 / 1/2” to 4” (Clamp)  Nominal pressure: 10bar / 150lb  Min. conductivity of measured liquid: 20μS/cm, 5 μS/cm on special request  Max. temperature of measured liquid: up to +150°C (302°F)  Material of electrodes: Hasteloy, Tantalum, Titanium, Platinum  Material of lining:Teflon  Material of flanges:carbon steel, ss-steel  Type of connection:Tri Clover (ASME BPE), DIN 11851 9 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

10 FLONET FF10XX.1  Design version: compact, remote (max. 50m of length of cable)  Measurement accuracy:±0,5% in range 1:20  Measuring range:0.1 to 10 m/s  Outputs:pulse, frequency, current 0(4) to 20mA, USB and RS485  Power supply:115/230V AC, 50/60Hz, 24V DC  Ambient temperature:-5 to +55°C (23° to 131°F)  Protection class:IP65/ IP67/IP68 10 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

11 FLONET FF10XX.1 Rated internal diameter a sensor length 11 Design versionCOMPACTREMOTE ConfigurationECONOMICCOMFORTECONOMICCOMFORT Type designationFF10X0.1FF10X4.1FF10X1.1FF10X5.1 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

12 FLONET FF10XX.1 12 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

13 FLONET FH10XX 13 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

14 FLONET FH10XX  Produced sizes: DN6 to DN400 (1/4” to 16”)  Nominal pressure: from 6 to 40bar / 150 to 600lb  Min. conductivity of measured liquid: 20μS/cm, 5 μS/cm on special request  Max. temperature of measured liquid: up to +150°C (302°F)  Material of electrodes: ss-steel 316Ti, Hasteloy, Tantalum, Titanium, Platinum  Material of lining:Hard/Soft rubber, special rubber WAGUNIT, Teflon  Material of flanges:carbon steel, ss-steel  Type of connection:flanged or wafer (up to DN200) 14 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

15 FLONET FH10XX  Type of flanges:EN, ANSI, AWWA, JIS, AS, BS  Design version:compact, remote (max. 50m of length of cable)  Measurement accuracy:±0,5% in range 1:20  Measuring range:0.1 to 10 m/s  Outputs:pulse, current 0(4) to 20mA (HART)  Power supply:115/230V AC, 50/60Hz, 24V DC  Ambient temperature:+5 to +55°C (23° to 131°F)  Protection class:IP67/IP68 15 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

16 FLONET FH10XX Rated internal diameter a sensor length 16 Design version CompactRemote ConfigurationECONOMICCOMFORTECONOMICCOMFORT Type designationFH1010FH1014FH1011FH1015 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic

17 FLONET FH10XX 17 ELIS PLZEŇ a. s., Luční 15, 301 64 Plzeň, Czech Republic